PT5503
Pressure transmitter
PT-025-SEG14-A-ZVG/US
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PT5503-00 — 27.04.2016 —
Outputs
Total number of outputs
1
Output signal
analogue signal
Number of analogue outputs
1
Analogue current output [mA]
4...20
Max. load [Ω]
(Ub - 8 V) / 21,5 mA; @8V = 0 Ω; @12V max. 200 Ω; @24V max. 750 Ω
Short-circuit proof
yes
Overload protection
yes
Measuring/setting range
Measuring range 0...25 bar 0...360 psi 0...2.5 MPa
Accuracy / deviations
Repeatability [% of the span]
< ± 0,05; (with temperature fluctuations < 10 K)
Characteristics deviation
[% of the span]
< ± 0,8; (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis)
Linearity deviation
[% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS)
Hysteresis deviation
[% of the span]
< ± 0,2
Long-term stability
[% of the span]
< ± 0,1; (per 6 months)
Temperature coefficient zero
point
[% of the span / 10 K]
< ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C)
Temperature coefficient span
[% of the span / 10 K]
< ± 0,1 (0...80 °C); < ± 0,3 (-40...0 °C); < ± 0,2 (80...125 °C)
Response times
Step response time analogue
output
[ms]
2
Operating conditions
Ambient temperature [°C]
-40...100
Storage temperature [°C]
-40...100
Protection
IP 67; IP 69K
Tests / approvals
EMC
compliant with UN ECE R10, rev. 5 (E1 compliant)
ISO 11452-2 100 V/m
DIN EN 61326-1
Shock resistance DIN EN 60068-2-27 500 g (1 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years]
704
UL approval
UL Approval no. J071
File number UL E174189
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request